ASTM A767 PDF

25 Jan ASTM A, Standard Specification for Zinc-Coating (Galvanized) Steel Bars for Concrete Reinforcement first and foremost specifies the. ASTM A/AM: Standard Specification for Zinc-Coated (Galvanized) Steel Bars for Concrete Reinforcement. ASTM A – Download as PDF File .pdf), Text File .txt) or read online. ASTM A

Author: Nilmaran Muktilar
Country: Senegal
Language: English (Spanish)
Genre: Health and Food
Published (Last): 24 November 2007
Pages: 242
PDF File Size: 20.44 Mb
ePub File Size: 4.51 Mb
ISBN: 448-3-15740-348-7
Downloads: 1273
Price: Free* [*Free Regsitration Required]
Uploader: Jugami

The mass of zinc coating shall conform to specified requirements. January 25, Authored by Dr. Stripping method, weighing before and after galvanizing, and microscopy method shall be used to referee the results obtained by magnetic thickness measurements.

Link to Active This link will always route to the current Active version of the standard. The specification also calls out specific recommended before galvanizing bending radii. In addition, since rebar is handled frequently during its installation, any tears or sharp spikes that make the material dangerous to handle are grounds for rejection.

These notes and footnotes excluding those in tables shall not be considered as requirements of the specification. Are you still looking for the right answer?

ASTM A767 – Galvanizing Steel Bars for Concrete Reinforcement – Rebar

Historical Version s – view previous versions of standard. It is informational only and not an official part of the standard; the full text of the z767 itself must be referred to for its use and application. Therefore, each system shall be used independently of the other.

Within the text, the SI units are shown in brackets. This post-treatment helps to prevent the formation z767 wet storage stain on the bars when they are in bundles at a job site and also promotes good adhesion of the galvanized rebar to the concrete it asfm placed in. As this evolved hydrogen gas travels through the concrete matrix toward the surface, voids can be created which weaken the bonding with the concrete or disturb the smoothness of the concrete surface.

TOP Related Articles  2SD2012 EBOOK

A retest shall be provided if the average zinc coating mass fails to meet the requirements. It is important to note reinforcing steel used in conjunction with structural wstm, welded to a fabricated assembly is not governed by ASTM A but rather ASTM A, the standard specification for zinc coatings on iron and steel products. Steel reinforcing bars bent cold prior to hot-dip galvanizing should be fabricated to a bend diameter equal to or greater than the specified values.

The galvanizer shall be permitted to subject the newly coated steel reinforcing bars to air or steam wiping to remove excess zinc from the bars. The values axtm in each system may not be exact equivalents.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. Newly galvanized steel can react with wet concrete and potentially form hydrogen gas as a product.

However, wire is not included. Number 12 and smaller bar must have a minimum of 3.

ASTM A – Galvanizing Steel Bars | American Galvanizer’s Association

This specification covers steel reinforcing bars with protective zinc coatings applied by dipping the properly prepared reinforcing bars into a molten bath of zinc.

Was this answer helpful? This abstract is a brief summary of the referenced standard. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. This cold working of the bars causes induced stresses that may be released after the bars are immersed in the molten F zinc bath.

TOP Related Articles  STRATHMORE CPA NOTES PDF

Rebar is commonly bent prior to the hot-dip galvanizing process. Leave this field blank. This specification also introduces a new requirement to the galvanized coating known as chromating. In order to help prevent and suppress this reaction, hot-dip galvanized rebar is dipped into a dilute chromate quench solution after being removed from the galvanizing kettle.

However, this single product specification introduces a few new requirements that apply solely to hot-dip galvanized rebar.

Combining values from the two systems may result in non-conformance with this specification. The galvanized coating shall be chromate treated. The mass of the coating shall be determined by magnetic thickness gage measurements.

Work Item s – proposed revisions of this standard. Historical Version s – view previous versions of standard Work Item s – proposed revisions of this standard Translated Version s: Table 5 below gives recommendations for bend diameters based upon the bare steel bar diameter before coating. The galvanizer is identified throughout this specification as asstm manufacturer.

Anyone making use of this information assumes all liability arising from such use.

Unique to this specification is also the requirement the galvanized bars be immersed in a heated, sodium dichromate solution immediately after the process. Galvanization shall be used to prepare reinforcing bars. The material provided herein has been developed to provide accurate and authoritative information about after-fabrication hot-dip galvanized steel. This material provides general information only and is not intended as a substitute for competent professional examination and verification as to suitability and applicability.